    shape representation for IfcWallStandardCase Description The Axis shape representation of an IfcWallStandardCase shall be restricted to The axis shall be at the base of the extrusion body of the IfcWallStandardCase The axis is positioned by the object local placement of the IfcWallStandardCase and not by the position coordinate system of the extrusion body The axis shall be parallel to the x axis of the object local placement for straight walls or the tangent of the Axis at the start point shall be parallel to the object local placement for round walls The direction of the axis or the direction of the tangent of the axis shall be in the direction of the positive x axis NOTE In most cases but not necessarily the Axis is collinear to the x axis The IFC import interfaces shall however also handle a wall axis that is parallel with offset to the x axis of the object local placement Previous CV 2x3 173 Next CV 2x3 175 Implementation get involved first steps and tools IFC2x3 impl guidance IFC Impl Agreements CV 2x3 174 IFC Impl Guide IFC Header Guide IFC4 impl guidance Implementer s community accompanying documents frequently asked questions Implementations Search Advanced Search

    Original URL path: http://www.buildingsmart-tech.org/implementation/ifc-implementation/ifc-impl-agreements/cv-2x3-174 (2016-02-11)
    Open archived version from archive


  • #CV-2x3-175 — Welcome to buildingSMART-Tech.org
    175 based on IFC2x3 effects IFC2x3 coordination view 2 0 date 24 Sep 2012 initiator ISG meeting in Helsinki summary agreement that all doors and windows shall have a body shape representation Description For all doors and windows it is required to export a Body representation This applies also for doors and windows with parametric definition by lining properties and panel properties Additionally the IfcDoorStyle IfcWindowStyle is mandatory to indicate which is the preferred definition by the use of the attribute ParameterTakesPrecedence In CV 2 0 the parametric definition is not certified but if both definitions are used explicit and parametric they have to be consistent By this agreement the import of IFC data into general IFC viewer applications is simplified and better overall support guaranteed This implementer agreement revokes the previous agreement CV 2x3 114 Previous CV 2x3 174 Next CV 2x3 176 Implementation get involved first steps and tools IFC2x3 impl guidance IFC Impl Agreements CV 2x3 175 IFC Impl Guide IFC Header Guide IFC4 impl guidance Implementer s community accompanying documents frequently asked questions Implementations Search Advanced Search IFC Dev Blog IFC Dev Blog More Registration This site contains content which is only available to registered users

    Original URL path: http://www.buildingsmart-tech.org/implementation/ifc-implementation/ifc-impl-agreements/cv-2x3-175 (2016-02-11)
    Open archived version from archive

  • #CV-2x3-176 — Welcome to buildingSMART-Tech.org
    the usage of position and orientation of the local placement All definitions are taken from the IFC4 documentation The location of the port is determined in the context of the local coordinate system of the element to which it belongs The PlacementRelTo relationship of IfcLocalPlacementshall point to the local placement of the masterIfcElementorIfcElementType relevant subtypes which is related to the IfcPort by the relationship objectIfcRelNestsfor fixed ports orIfcRelConnectsPortToElementfor dynamic ports Axis orientation of local placement IfcPort The axis points in the direction of the physical connection from the product IfcDistributionPort The axis direction has to be used together with the attribute FlowDirection The Axis points in the direction of the physical connection away from the product if FlowDirection equals SOURCE or SOURCEANDSINK or NOTDEFINED or points opposite direction to the product if the FlowDirection equals SINK The RefDirectio points in the direction of the local X axis of the material profile where the local Y axis points up if looking towards the Axis where the local X axis points right Previous CV 2x3 175 Next CV 2x3 177 Implementation get involved first steps and tools IFC2x3 impl guidance IFC Impl Agreements CV 2x3 176 IFC Impl Guide IFC Header Guide

    Original URL path: http://www.buildingsmart-tech.org/implementation/ifc-implementation/ifc-impl-agreements/cv-2x3-176 (2016-02-11)
    Open archived version from archive

  • #CV-2x3-177 — Welcome to buildingSMART-Tech.org
    opening geometry which is subtracted from the element geometry Then the element geometry of the wall slab etc must be defined without those openings If the element geometry however is already defined with openings for instance using CSG or Brep representation type including the opening geometry no IfcOpeningElement shall be used to assign the opening in addition The opening geometry of an element with openings or other subtraction such as recesses etc shall be defined only once either by the IfcOpeningElement instance or by the element geometry using Brep or CSG representation type It is illegal to define the same opening geometry twice by the element geometry and an associated IfcOpeningElement NOTE 1 In the case of an IfcWall or IfcSlab having a Brep representation type with openings already resolved no IfcDoor or IfcWindow can be associated to the opening Such IfcDoor or IfcWindow objects need to be defined as free standing door window without the IfcRelFillsElement relationship NOTE 2 In case of aggregated elements such as an aggregated wall having IfcBuildingElementPart s the agreement also applies to the parts i e if the aggregated IfcWall has an IfcOpeningElement associated then the opening volume shall not already be cut out

    Original URL path: http://www.buildingsmart-tech.org/implementation/ifc-implementation/ifc-impl-agreements/cv-2x3-177 (2016-02-11)
    Open archived version from archive

  • #CV-2x3-178 — Welcome to buildingSMART-Tech.org
    view 2 0 date July 2013 initiator official buildingSMART certification 2 0 program summary Agreement on using IfcRelConnectsElements for assigning IfcDoor IfcWindow to building elements without IfcOpeningElements Description The proper way to assign an IfcDoor IfcWindow element to a building element is by using IfcRelVoidsElement IfcOpeningElement IfcRelFillsElement In some situations an IfcOpeningElement is not available If the subtraction within the building elements geometry is already done and a feature element can not be assigned If the IFC export is used for presentation only Presentation View In this cases with IfcRelConnectsElements it is possible to represent this relation without losing information The IfcRelConnectsElements RelatingElement then points to the building element such as IfcWall whereas the IfcRelConnectsElements RelatedElement points to the IfcOpeningElement Note The relation IfcRelConnects for IfcDoors IfcWindows should be only used if there is no other solution and should only be used for Brep geometries Previous CV 2x3 177 Next CV 2x3 180 Implementation get involved first steps and tools IFC2x3 impl guidance IFC Impl Agreements CV 2x3 178 IFC Impl Guide IFC Header Guide IFC4 impl guidance Implementer s community accompanying documents frequently asked questions Implementations Search Advanced Search IFC Dev Blog IFC Dev Blog More Registration This site

    Original URL path: http://www.buildingsmart-tech.org/implementation/ifc-implementation/ifc-impl-agreements/cv-2x3-178 (2016-02-11)
    Open archived version from archive

  • #CV-2x3-180 — Welcome to buildingSMART-Tech.org
    IFC2x3 coordination view 2 0 date Sep 2013 initiator official buildingSMART certification 2 0 program summary Agreement on Color Priorities in the Coordination View Description To clarify the assignment priority of color to shape representations refer to CV 2x3 131 by the following sequence by one explicit color per solid For Boolean results by color assigned to Boolean result If no color is assigned to the Boolean result then the color from the 1st operand used The IfcMappedItem shall NOT have a color assignment if no color per solid is provided it must be from the assigned material color if no material color than the color is defined by the assigned CAD Layer It is the responsibility of the importing application to display the correct color for shared geometries on different layers or with different material representations Previous CV 2x3 178 Next CV 2x3 181 Implementation get involved first steps and tools IFC2x3 impl guidance IFC Impl Agreements CV 2x3 180 IFC Impl Guide IFC Header Guide IFC4 impl guidance Implementer s community accompanying documents frequently asked questions Implementations Search Advanced Search IFC Dev Blog IFC Dev Blog More Registration This site contains content which is only available to registered

    Original URL path: http://www.buildingsmart-tech.org/implementation/ifc-implementation/ifc-impl-agreements/cv-2x3-180 (2016-02-11)
    Open archived version from archive

  • #CV-2x3-181 — Welcome to buildingSMART-Tech.org
    of ParameterTakesPrecedence number CV 2x3 181 based on IFC2x3 effects IFC2x3 coordination view 2 0 date Sep 2013 initiator official buildingSMART certification 2 0 program summary Agreement on use of ParameterTakesPrecedence Description Within the IFC2x3 Coordination View 2 0 each door and window shall have an explicit shape representation and one should not rely on the lining and panel parameters added Those shall only be used for informational purposes Therefore it is agreed for IfcWindow and IfcDoor the parameter ParameterTakesPrecedence is always FALSE and explicit geometry of the IfcWindow and IfcDoor is always provided for backward compatibility a receiving application can always assume ParameterTakesPrecedence is interpreted as FALSE even if the files indicates a TRUE or NULL value and lining and panel parameters are attached Previous CV 2x3 180 Next CV 2x3 182 Implementation get involved first steps and tools IFC2x3 impl guidance IFC Impl Agreements CV 2x3 181 IFC Impl Guide IFC Header Guide IFC4 impl guidance Implementer s community accompanying documents frequently asked questions Implementations Search Advanced Search IFC Dev Blog IFC Dev Blog More Registration This site contains content which is only available to registered users To get access to the content you must be a registered

    Original URL path: http://www.buildingsmart-tech.org/implementation/ifc-implementation/ifc-impl-agreements/cv-2x3-181 (2016-02-11)
    Open archived version from archive

  • #CV-2x3-182 — Welcome to buildingSMART-Tech.org
    local placement number CV 2x3 182 based on IFC2x3 effects IFC2x3 coordination view 2 0 date Sep 2013 initiator official buildingSMART certification 2 0 program summary Agreement to clarify the export of a Building Storey and its local placement Description There are two ways in IFC to express the storey elevation by IfcBuildingStorey Elevation by the z Value of the IfcLocalPlacement of IfcBuildingStorey It is hereby agreed that The value of IfcBuildingStorey Elevation should be the same as the Z value of the local placement of the IfcBuildingStorey so they are redundant or it should be omitted The Z value of the local placement of the IfcBuildingStorey is the preferred method of locating the building storey and its associated elements The value of the IfcBuildingStorey Elevation shall not be used within geometric positioning Previous CV 2x3 181 Next CV 2x3 183 Implementation get involved first steps and tools IFC2x3 impl guidance IFC Impl Agreements CV 2x3 182 IFC Impl Guide IFC Header Guide IFC4 impl guidance Implementer s community accompanying documents frequently asked questions Implementations Search Advanced Search IFC Dev Blog IFC Dev Blog More Registration This site contains content which is only available to registered users To get access

    Original URL path: http://www.buildingsmart-tech.org/implementation/ifc-implementation/ifc-impl-agreements/cv-2x3-182 (2016-02-11)
    Open archived version from archive



  •